Start a conversation

Pivotal Client Error: "Unable to load system 'Offline' Cannot load metadata using UxClient"

Article Original Creation Date: 2017-06-14

Overview

Users are unable to launch PivotalClient due to the UX Client metadata error (see the below stack trace) after a system is restored from a previous version to a higher platform version:

Error from Pivotal Event:
[System Name: Offline]
Unable to load system 'Offline'.
Cannot load metadata using UxClient.Metadata.Activities.UxRecordLinkCollectionBuilder.
====================
Cannot load metadata using UxClient.Metadata.Activities.UxRecordLinkCollectionBuilder.
Pivotal.DataAccess: Unable to find the column 'Record_Link.Office_Ordinal'.
   at Pivotal.DataAccess.DataSetBuilder.GetSql(DbSchemaType dbSchemaType, TableSpec tableSpec, DbParameterCollection parameters, String sqlComment)
   at Pivotal.DataAccess.DataSetBuilder.BuildDataSet(DbSchemaType dbSchemaType, DataSpec dataSpec, String sqlComment)
   at Pivotal.MetadataLoader.PivotalMetadataLoader.LoadMetadataType(MetadataService metaService, DataSetBuilder dsBuilder, String assemblyName, String className)
   at Pivotal.MetadataLoader.PivotalMetadataLoader.LoadMetadataFromPath(MetadataService metaService, DataSetBuilder dsBuilder, String pathName)

--- End of inner exception stack trace ---

Pivotal.MetadataLoader: Cannot load metadata using UxClient.Metadata.Activities.UxRecordLinkCollectionBuilder.
   at Pivotal.MetadataLoader.PivotalMetadataLoader.LoadMetadataFromPath(MetadataService metaService, DataSetBuilder dsBuilder, String pathName)
   at Pivotal.MetadataLoader.PivotalMetadataLoader.LoadMetadata(Object system, String path)

====================
  HRESULT = 0x80131509 -- Unknown error

  Function = CRSystemBase::LoadGenericMetadata

  Occurred in RSysBaseLoad.cpp on line 6158.

  Compiled on Jun  2 2017, modified on Fri Jun  2 06:26:59 2017.
====================
  HRESULT = 0x80131509 -- Unknown error

  Function = CRSystemBase::InitMetaInfo

  Occurred in RSysBaseInit.cpp on line 1820.

  Compiled on Jun  2 2017, modified on Fri Jun  2 06:26:59 2017.
====================
  HRESULT = 0x80131509 -- Unknown error

  Function = CRSystemBase::Init

  Occurred in RSysBaseInit.cpp on line 826.

  Compiled on Jun  2 2017, modified on Fri Jun  2 06:26:59 2017.
====================

Unable to load system 'Offline'.

  HRESULT = 0x80131509 -- Unknown error

  Function = CRLogin::GetValidSystem

  Occurred in RLogin.cpp on line 310.

  Compiled on Jun  2 2017, modified on Fri Jun  2 06:26:59 2017.

 

Environment

Pivotal Client 6.5.3.1
 

Root Cause

An incomplete upgrade is causing the error.

 

Resolution

  1. Restore Pivotal Toolkit 6.5.3.1 RDF to the customization system's Business Module (BM). 
  2. Perform an ACC (Apply Customization Changes).
  3. Open Pivotal Toolkit for the customization system so that the BM upgrade can complete. The new .rdf file can be found on the installation package in the path:\TK6.5.3HF1\Customization Modules
  4. Accept the Upgrade Business Module option.
  5. Reboot the Business Server and when ready, reopen it.

 

Validation

Once the upgrade is completed, the error message no longer appears.